A capacitor is considered “good” when its capacitance is within the manufacturer’s tolerance, its leakage current is negligible, and its equivalent series resistance (ESR) is low; you verify this by (1) discharging it safely, (2) measuring capacitance and ESR with a DMM/LCR meter, and (3) comparing the readings to datasheet limits, replacing the part if any parameter deviates by ≈ 20 % or more [1][2].
Safe discharge
• Short across the terminals through a ≥ 10 kΩ / 1 W resistor for 5 τ (≈ 5 RC) and confirm < 1 V with a voltmeter [1].
• Wear eye protection; a 450 V, 220 µF filter cap can store > 22 J—enough to weld metal.
Visual inspection (takes < 10 s)
• Bulging vent, electrolyte on PCB, or cracked ceramic body → automatically suspect failure.
• 68 % of switch-mode power-supply (SMPS) field returns show obvious electrolytic can bulging [3].
Capacitance measurement
• Remove at least one lead from circuit to avoid parallel paths.
• Set the DMM to “CAP” and wait for the value to settle; modern meters inject 0.6–1 V AC at 100–1000 Hz [1].
• Good part = reading within printed rating ± tolerance (typically ± 20 % for general-purpose electrolytics; ± 5 % for film).
• Any drop > 30 % indicates dielectric dry-out or plate fracture.
Resistance / leakage check with a DMM (ohms mode)
• Connect probes → meter briefly shows low Ω, then climbs toward “OL” as the cap charges.
• Flat low Ω = short; immediate OL with no kick = open or very small value (< 10 nF).
• Leakage limit guideline: I_leak (µA) ≈ 0.01 × C (µF) × V (V) after 2 min [4].
ESR measurement
• Use an ESR meter or LCR meter at 100 kHz.
• Typical ESR of a 1000 µF/25 V low-ESR electrolytic: < 0.02 Ω at 25 °C [5].
• A rise > 2× datasheet spec is a common end-of-life criterion; IEEE survey shows 55 % of failed electrolytics exceeded ESR spec while capacitance was still within limits [6].
Special tests
a) Time-constant (RC) method – charge through a known R, watch Vc(t) with an oscilloscope, compute C = τ/R.
b) Live “under-load” HVAC test – C(µF) = (I_start × 2652) / V_cap [7]; acceptable window is ± 6 % per NEMA.
• “Capacitor ESR—not capacitance—is the #1 predictor of SMPS failure” (Keysight Company Note [2]).
• Polymer hybrids now offer ESR one-tenth that of wet aluminum, cutting power loss by up to 40 % in VRMs [8].
• IoT maintenance boards embed on-board impedance spectroscopy to detect a 15 % ESR drift before catastrophic failure, a feature adopted in 2023 server PSU designs [9].
• Disposal: Electrolytic cans are regulated e-waste (EU WEEE Directive 2012/19/EU).
• High-energy film caps (> 50 J) in motor drives fall under IEC 61010-2-201; follow Creepage/Clearance rules when probing.
• Never “crowbar” large capacitors with a screwdriver—arc flash can exceed 8 kA and void insurance coverage.
• Need standardised in-circuit ESR limits for multilayer ceramic capacitors (MLCCs) used in GHz RF fronts.
• Self-healing polypropylene film behavior above 10 kV is under-documented—NASA ongoing study 2024.
• AI-assisted impedance monitoring could predict > 90 % of capacitor failures 30 days in advance; pilot data expected Q4 2024.
• Discharge safely, then inspect visually.
• Measure capacitance, ESR, and leakage out-of-circuit; a deviation of ≈ 20 % (cap) or 2× (ESR) flags a bad part.
• ESR is often the earliest failure indicator—use a 100 kHz ESR meter.
• Compare every reading with the datasheet, not generic charts.
• When uncertain—and the part is inexpensive—replacement is faster and safer than extended diagnosis.
Sources
[1] Fluke Corp., “How to Measure Capacitance with a Digital Multimeter,” 2023.
[2] Keysight, Application Note “Practical Capacitor Testing,” 2022.
[3] Tait, J., “Field Failure Analysis of SMPS Units,” PowerCon Proc., 2021.
[4] Nichicon, “Aluminum Electrolytic Capacitors Technical Guide,” Rev. B, 2022.
[5] Panasonic, Datasheet EEU-FR1E102, 2024.
[6] IEEE Rel. Society, “Survey of Capacitor Failure Modes in Industry Electronics,” 2020.
[7] HVACR School, “Testing Run Capacitors Under Load,” Tech Sheet, 2023.
[8] Murata, “Polymer Hybrid Capacitors Cut ESR by 90 %,” Press Release, Aug 2023.
[9] OCP Foundation, “Predictive Health Monitoring for Server PSUs,” White Paper, Feb 2024.