Nie, dziękuję Przekieruj mnie tamDelonghi ECAM22.110.B water no coming during flushing and also during coffe preparing .
Infuzer is going up for moment stop then going down , pump not start
For a DeLonghi ECAM 22.110.B / Magnifica S, the symptom:
usually means the machine is aborting the brew/rinse sequence before it reaches the pump stage.
The most likely causes are:
Because the pump never starts, do not immediately replace the pump. First check why the control board is sending the infuser back down.
In this machine, the pump does not start immediately. The control sequence is approximately:
In your case, the machine moves the infuser up, pauses, and returns it downward. That means the control board is probably saying:
“The brew unit did not reach the correct position, or something is wrong mechanically/electrically, so I will cancel the cycle.”
Therefore the pump is not starting because the machine never reaches the permitted pumping stage.
This is one of the most common causes.
The upper microswitch tells the control board that the infuser has reached the top position. If this switch is:
then the machine will move the infuser up, fail to detect the top position, and send it back down.
Typical signs:
What to do:
Expected result:
If the reading is unstable or does not change, replace the microswitch.
Also inspect for water leakage above or around the switch. A leaking upper piston seal can drip hot water/minerals onto the switch and corrode it.
If the infuser is stiff, the drive motor may not be able to push it fully upward. The controller may detect excessive load and reverse the motor.
Remove the infuser and inspect:
Clean the infuser with warm water. Do not use aggressive detergent. Let it dry, then apply a small amount of food-grade silicone grease to:
Do not over-grease. Excess grease attracts coffee powder and makes the mechanism dirty again.
Also check the vertical guide tracks inside the machine. Coffee residue can accumulate there and increase friction.
The upper brewing piston is the part at the top that the infuser presses against. If it is blocked by scale or coffee deposits, the infuser may hit resistance before the microswitch is triggered.
Possible symptoms:
Check:
If the upper piston is heavily scaled or leaking, it may need cleaning, seal replacement, or complete replacement.
The infuser is moved by a motor-driven transmission screw/spindle. If the spindle nut or carriage is worn, the motor may rotate but the infuser may not reach the exact position required.
Typical signs:
With the machine unplugged, check for abnormal looseness in the brew unit carriage. Some play is normal, but large movement or slipping indicates transmission wear.
Possible solution:
The brew drive motor usually has a feedback sensor that allows the control board to count motor movement. If this feedback is missing or incorrect, the controller may lose track of the infuser position and abort the cycle.
Check:
A Hall sensor fault can produce symptoms similar to a bad microswitch: short movement, stop, reverse.
Because your pump does not start during flushing or coffee preparation, it may appear that the pump is faulty. But in this case, the pump may simply not be commanded on.
Try to test the pump in a mode that does not depend on the brew group position.
On many DeLonghi machines, you can test water flow through the steam/hot-water circuit:
Possible results:
| Result | Meaning |
|---|---|
| Pump runs and water/steam comes from steam wand | Pump is probably OK; problem is brew-position, microswitch, upper piston, or drive system |
| Pump hums but no water comes | Airlock, blocked flow path, scaled thermoblock, blocked valve, or weak pump |
| Pump completely silent | Pump not powered, faulty pump, thermal protector, wiring, triac/control board fault |
If the pump runs from the steam wand but not during coffee/rinse, focus on the infuser position detection system, not the pump.
Before opening the machine:
If the same up-stop-down movement happens again, continue.
Do not use petroleum grease, WD-40, cooking oil, or general-purpose machine oil. These are not suitable for food-contact coffee machine mechanisms and may damage seals.
With the infuser installed, observe carefully:
Interpretation:
This is the most important electrical test.
Unplug the machine before measuring.
Use a multimeter:
The switch must change cleanly every time.
If it is intermittent, replace it. Intermittent microswitches can pass a test once but fail during actual operation due to vibration or weak contact pressure.
Look for:
If water has leaked onto the microswitch, replace the switch and repair the leak. Otherwise the new switch may fail again.
If possible, activate hot water/steam output.
If the pump works through the steam wand, the pump and main pump drive are probably functional.
If the pump is silent in every mode, then check:
A typical vibration pump is a mains-voltage component. Do not test it live unless you are qualified to work safely with mains voltage.
If you are comfortable with electrical testing:
With the machine unplugged, disconnect one pump terminal and measure pump coil resistance. Depending on the pump model and voltage, it is often in the range of several hundred ohms to a few kilo-ohms. An open circuit means the pump coil is failed.
Should switch clearly between open and closed.
If the machine never reaches ready temperature, pump operation may be inhibited. The thermoblock resistance is commonly tens of ohms, depending on version and supply voltage. Also check thermal fuses for continuity.
Inspect the small sensor board on or near the brew drive motor. Look for:
This machine contains:
Before opening:
If testing live, use proper insulation, RCD/GFCI protection, and one-hand working practice. If unsure, take it to a service technician.
Recommended order of repair:
For your described symptom, I would check the upper microswitch and upper piston area first. The pump is probably not starting because the machine cancels the operation before the pump is allowed to run.
Your DeLonghi ECAM22.110.B is most likely stopping because the control board does not detect the infuser in the correct upper brewing position. The main suspects are the upper brew piston microswitch, a stiff/jammed infuser or upper piston, or a worn drive transmission. The pump may be good; it is probably not being activated because the brew cycle is aborted early. Clean and lubricate the infuser first, then test the upper microswitch and inspect the upper piston/drive mechanism.