logo elektroda
logo elektroda
X
logo elektroda

FirstChip YF2024 NAND USB flash tool for FC1179 recovery

User question

driver tool for nand firstchip YF2024

Artificial Intelligence ResponseLABEL_AI_GENERATED

Direct answer to the question

For a USB/NAND flash drive detected as FirstChip YF2024 / chipYF2024, you usually do not need a normal Windows driver. You need the FirstChip Mass Production Tool, normally the FC1179 MPTool branch.

Use:

  • FirstChip FC1179 MpTools V1.0.7.2 / FirstChip_MpTools_20240221
  • If that does not detect the drive, try older FC1178/FC1179 tools such as:
    • FirstChip FC1178/FC1179 MpTools V1.0.5.2 — 2022-06-01
    • Older FC1179 builds if your NAND ID is unsupported

The 2024-02-21 FirstChip package is widely referenced for FC1179-class FirstChip USB controllers, and community reports list it for devices showing NAND USB2DISK, VID FFFF / PID 1201, or similar recovery-mode identifiers. (elektroda.com)

Detailed problem analysis

1. “Driver” vs “MPTool”

If Windows shows the device as:

  • NAND USB2DISK
  • USB Mass Storage Device
  • No Media
  • 0 Bytes
  • VID = FFFF, PID = 1201
  • FirstChip chipYF2024 / FC1179

then the problem is usually not a missing Windows driver. Windows already has a generic USB mass-storage driver. The failure is normally inside the USB flash controller firmware, NAND mapping table, bad-block table, or translator layer.

For that reason, ordinary tools such as:

  • Windows Format
  • Disk Management
  • diskpart
  • SD Card Formatter
  • generic partition tools

usually cannot fix it.

You need a controller-specific MPTool. MPTool means Mass Production Tool. It reinitializes the controller, scans the NAND, builds a new bad-block table, and creates a new logical USB storage area.

2. Correct tool family for FirstChip YF2024

The likely tool family is:

Detected controller Recommended tool
FirstChip chipYF2024 Try FC1179 MPTool 20240221
FirstChip FC1179 / FC1179S / FC1179AB FC1179 MPTool
FirstChip FC1178 / FC1178BC FC1178/FC1179 MPTool, sometimes older builds work better
USB 3.x FirstChip controller May require a different FirstChip U3 MPTool branch

Current community references still point to FirstChip_MpTools_20240221 / FC1179 MpTools V1.0.7.2 as the main package for FC1179-class devices. (elektroda.com)

Practical guidelines

Step 1: Identify the controller and NAND

Before flashing, use a USB diagnostic utility such as:

  • ChipGenius
  • ChipEasy
  • Flash Drive Information Extractor

Record these fields:

  • Controller vendor: FirstChip
  • Controller part number: chipYF2024, FC1179, FC1178BC, etc.
  • VID/PID
  • Flash ID code
  • Reported capacity
  • Real NAND vendor, if shown

The Flash ID is important. If the MPTool database does not support that NAND ID, the tool may show errors such as Unknown Flash or fail early.

Step 2: Use FirstChip MPTool

Recommended starting point:

  • FirstChip_MpTools_20240221
  • Also known in listings as FirstChip FC1179 MpTools V1.0.7.2

FlashBoot and Elektroda references identify the 2024-02-21 package as an FC1179 FirstChip MPTool package. (flashboot.ru)

Step 3: Run safely

Use this procedure:

  1. Use a Windows PC.
  2. Plug the flash drive directly into a rear motherboard USB port.
  3. Prefer a USB 2.0 port if available.
  4. Run the MPTool as Administrator.
  5. If the interface is Chinese, check the top-right area for language selection.
  6. Let the tool auto-detect the NAND first.
  7. Start with default settings.
  8. If normal scan fails, try a stronger scan mode such as:
    • Clear + Factory Scan
    • Low Level Format
    • Factory Scan
  9. After success, remove and reconnect the drive.
  10. Test the full real capacity using H2testw, F3, or another full write/read verification tool.

Important warning

MPTool operation is destructive.

It will normally erase:

  • all user data,
  • the existing partition table,
  • controller mapping information,
  • factory configuration.

If the data is important, do not run MPTool. Send the device to a NAND/flash data recovery lab instead. Once the controller translator is rebuilt, previous data recovery may become much harder or impossible.

Common errors

Symptom / error Likely cause Action
Tool does not detect USB Wrong tool branch, bad USB port, controller not in supported mode Try USB 2.0 port, different MPTool version
Unknown Flash NAND ID not in tool database Try newer or different FirstChip MPTool build
No Media / 0 Bytes Controller cannot initialize NAND mapping Use MPTool factory scan
Capacity becomes smaller after repair Original drive was fake-capacity or NAND has many bad blocks Use the smaller verified capacity
Error during scan Bad NAND, unstable power, unsupported NAND Try direct port; if repeated, NAND may be physically failing

Brief summary

For FirstChip YF2024 / chipYF2024 NAND USB flash, search for and use:

FirstChip FC1179 MpTools V1.0.7.2 — 2024-02-21
or
FirstChip_MpTools_20240221

This is not a normal driver; it is a low-level USB flash production/recovery tool. Use it only if you do not need the existing data, because the process is destructive.