• Disconnect power, remove the fuse, and inspect it—a broken/melted element or dark deposit usually means it is blown.
• Confirm with a multimeter continuity / resistance test: ≤1 Ω = good, “OL”/∞ Ω = blown.
• If removal is impossible, measure voltage across the installed fuse under power: ≈0 V = good, full supply voltage = blown.
Nature of a fuse
• One-time, sacrificial conductor sized to melt when current exceeds its time-current curve.
• Types: cartridge (glass, ceramic), blade (ATO/mini), radial/axial lead, SMD chip, resettable polymer (PPTC), electronic “e-fuses”.
Failure indicators
2.1 Visual (out-of-circuit)
– Glass: open element, beads, sooting, metal spatter.
– Ceramic: may show end-cap discoloration only.
– Blade: fractured “U” link visible through plastic.
– SMD: rarely shows damage; test electrically.
2.2 Electrical confirmation
a) Continuity mode (preferred)
– Remove fuse; meter beeps/≈0 Ω → good, silence/∞ Ω → open.
b) Resistance mode (200 Ω range)
– 0–1 Ω typical; >5 Ω suspicious; ∞ Ω blown.
c) In-circuit voltage drop
– Place probes on both fuse ends while powered.
– ΔV ≈ 0 V → good; ΔV ≈ supply voltage → blown.
– Suitable only when you understand circuit ground reference and safety clearances.
d) Test-light / dedicated fuse tester—quick Go/No-Go in automotive panels.
2.3 Special cases
– Hairline cracks in end-caps or press-fit terminations give intermittent opens; thermal tap-test with meter can reveal them.
– Slow-blow fuses may show slight darkening yet still be intact; always confirm electrically.
Why confirmation matters
• A fuse is a symptom: repeated blowing implies sustained over-current, short, motor stall, wrong rating, or downstream semiconductor failure.
• Substituting a higher-rated fuse defeats protection and violates IEC/UL/NEC safety compliance.
Interpreting time-current characteristics
• Fast-acting (F) fuses blow in ≤10 ms at 10× I_RATED.
• Time-delay/slow-blow (T) tolerate 5–20× inrush for tens–hundreds of ms.
• Match replacement not only for I and V but also speed, breaking capacity (IEC 60127 / UL 248).
Modern alternatives
• PPTC resettable fuses trip thermally and automatically reset once power is removed; test by measuring low resistance (<0.2 Ω) versus tripped high resistance (kΩ).
• Electronic e-fuses and smart power switches report fault flags—OBD-II style diagnostics in cars, I²C in servers.
• Transition from traditional blade fuses to solid-state power distribution modules (SPDM) in EVs and ADAS; diagnostic via CAN/I²C fault registers rather than continuity testing.
• Consumer products increasingly use SMD chip fuses for weight and cost; require meter testing because they lack visible element.
• IEC 60127-8:2022 added nano-fuses for USB-C and PD3.1 48 V rails; very low RFUSE (<10 mΩ) demands four-wire measurement for accurate diagnosis.
Ohmic model of a good fuse:
\[ R\text{fuse} \approx \rho \frac{L}{A} + R\text{termination} \ (typically <1\ \Omega) \]
Voltage drop method rationale:
\[ V{AB} = I \times R\text{fuse} \]
In open state \(R_\text{fuse}\rightarrow \infty\), current → 0, hence full supply appears across terminals.
Example—Automotive 12 V system:
– Measure 12.4 V battery.
– Across ATO-20 fuse: 0 V ⇒ good; 12.4 V ⇒ blown.
• North-American residential circuits: NEC 240.60 mandates fuses UL-listed for the enclosure; defeating them violates code and insurance policies.
• EU Low-Voltage Directive (LVD) and CE marking require fuses conforming to IEC 60127/60269; using unapproved substitutes jeopardizes product safety certification.
• Safety: live-circuit testing must follow OSHA/EN 50110 lock-out–tag-out (LOTO) and PPE guidelines; CAT-rated multimeters only.
• Measuring in-circuit continuity on low-voltage logic boards may give false positives through parallel paths—always test out-of-circuit when practical.
• Some miniature fuses have internal thermal cutoff plus fuse; after moderate overload they may show normal continuity when cold but open when hot—replace if suspect.
• Study IEC 60127-2 time-current curves to understand nuisance blowing.
• Explore solid-state over-current protection ICs (e.g., TPS2595 e-Fuse) as an alternative to mechanical fuses.
• Investigate resettable PPTC behaviour under repeated trip cycles and ageing.
• Review UL 248-14 for automotive blade fuses and ISO 8820-10 for EV high-voltage fuse standards.
A blown fuse usually reveals itself visually, but the definitive test is an electrical one: an intact fuse shows near-zero resistance or zero voltage drop, while a blown fuse shows infinite resistance or full supply voltage across its terminals. Always disconnect power, use proper PPE, and match all ratings when replacing. Recurrent fuse failure signals a deeper circuit fault that must be addressed before safely restoring operation.