• Identify the exact model designation (e.g. VUW 286/5-5) – diagram sheets differ in connector counts and accessory options.
• Use only the sheet that matches both power band and DHW capability.
• All live (230 V~) and safety-critical connections are clearly separated from 24 V SELV (Safety Extra-Low Voltage) on the drawings.
• Work must be carried out by a competent, suitably certified engineer – this is a gas appliance subject to national regulations.
The ecoTEC plus VUW family is a wall-hung condensing combi boiler (“VUW” = gas-fired combination appliance for Versorgung u. Warmwasser). Each variant shares a common electrical architecture organised around the main control PCB (“eBUS board”). The wiring diagram is therefore split into functional blocks:
Mains input & internal power supply
• Connector X1: L, N, PE (earth) via 3.15 A quick-blow fuse (F1).
• SMPS on the PCB delivers +24 V DC (protected by fuse F2) and +5 V logic rails.
High-voltage loads (switched 230 V~)
• Fan (X11), Pump (X24), Diverter-valve motor (X41), Ignition transformer (X16).
• Driven by PCB relay outputs; depicted on the diagram with dashed safety interlocks.
Low-voltage SELV loads and sensors
• Modulating gas valve (X25, 24 V DC, PWM).
• NTC temperature sensors (flow, return, DHW); shown as variable resistors.
• Water pressure sensor (X22) and Hall-type flow sensor for DHW recognition.
Communication & external controls
• eBUS (X100, polarity-free twin core) for Vaillant VRC/VRT controls.
• 24 V room-thermostat interface (RT) and 230 V switched-live interface (STB) – only one may be used at a time; factory link provided.
• Burner-off contact and fault relay output for BMS integration.
Safety chain
• Over-temperature stat, flue gas sensor, air-pressure switch (if fitted) and ionisation detection form a redundant shut-down path; depicted with thick outline on the diagram.
• Each safety device is shown in its safe (normally-closed) state.
Connector legend (most frequent across 5-5 generation)
X1 … mains, X2 … front-panel interface, X11 … fan, X12 … ignition, X16 … pump (new HE pumps use PWM+Hall return), X18 … diverter, X20 … low-voltage bus, X22 … pressure, X24 … external 230 V RT, X25 … gas valve, X30/31 … NTC sensors, X41 … PWM pump supply.
Colour code (EN 60757 / Vaillant convention)
BN = brown (Live) BU = blue (Neutral) GN/YE = earth GY = grey (signal) WH = white (sensor). Low-voltage pairs often orange or violet.
Practical reading tips
• The latest ecoTEC plus generation (6/5-7) keeps the same connector nomenclature but introduces LIN-bus high-efficiency pumps instead of PWM. The manual revision 0020274719_02 (2023) reflects this.
• Vaillant is gradually migrating from proprietary eBUS to VCI (Vaillant CAN Interface) for hybrid systems; forthcoming manuals will add CAN wiring to the diagrams.
• Opentherm is still not native; it requires the VR 33 or VR 34 interface board – shown as module X90 on the newest diagrams.
Example: reading the “Combi 12–35 kW” sheet
Analogy: treat the control PCB like an automotive ECU. 24 V DC is its “battery”, NTC sensors are “engine sensors”, gas valve = “injector”, fan = “turbo”. The wiring diagram is therefore similar to a car wiring loom map.
• In the UK, electrical work inside a gas boiler is governed by Part P of the Building Regulations and Gas Safety (Installation & Use) Regs 1998. Similar laws apply EU-wide (Directive 2009/142/EC, now Regulation (EU) 2016/426 – GAR).
• The diagram is copyrighted by Vaillant Group; redistribution for commercial purposes is prohibited. Provide the link, not a scanned clip, unless you have Vaillant’s written permission.
• Only Gas Safe (UK) / RGI (IE) / certified installers may break the combustion-sealed case.
Potential challenges & mitigation
• Mis-identifying connectors (X24 vs X24a) – always cross-reference the component list in the manual.
• Mixed-voltage conduit – use segregated trunking; maintain ≥6 mm clearance between 24 V and 230 V conductors.
• Condensation inside the harness – if the diagram shows “drip loop”, reproduce it exactly.
• Examine Vaillant Service Bulletin SB-008-2022 for updated pin-outs when retro-fitting VR 720 f weather sensor.
• Monitor emerging CAN-based control (VCI) – expected to replace eBUS after 2025.
• Investigate hydrogen-ready versions (H2 20 %) – additional flame ionisation electronics, new symbols to appear on diagrams.
• Resources: Vaillant “ServiceTech” app (Android/iOS) – interactive wiring diagram navigator; IET Code of Practice for In-service Inspection and Testing of Electrical Equipment (PAT) for annual checks.
The electrical diagram you need is in the official Vaillant ecoTEC plus VUW Installation & Service manual (e.g. doc #0020244997 _07, pages 64-71). Select the sheet that matches your model’s power band and DHW configuration. The drawing shows all mains, SELV, sensor, pump, fan and external control connections with connector numbers (X1 … X100), making diagnosis or integration straightforward. Always isolate, follow national gas/electrical regulations and, if in doubt, engage a certified engineer.